CVE-2018-19615

Estado: ModificadaMedia (6.1)—

Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions. A remote attacker could inject arbitrary code into a targeted user’s web browser to gain access to the affected device.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-19615",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-12-26T21:29:02.120",
  "references": [
    {
      "url": "http://packetstormsecurity.com/files/150600/Rockwell-Automation-Allen-Bradley-PowerMonitor-1000-XSS.html",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.securityfocus.com/bid/106333",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.securityfocus.com/bid/108538",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-04",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.exploit-db.com/exploits/45928/",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://packetstormsecurity.com/files/150600/Rockwell-Automation-Allen-Bradley-PowerMonitor-1000-XSS.html",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/106333",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/108538",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-04",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.exploit-db.com/exploits/45928/",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions. A remote attacker could inject arbitrary code into a targeted user’s web browser to gain access to the affected device."
    },
    {
      "lang": "es",
      "value": "Rockwell Automation Allen-Bradley PowerMonitor 1000 todas las versiones. Un atacante remoto podrÃa inyectar código arbitrario en el navegador web de un usuario objetivo para obtener acceso al dispositivo afectado"
    }
  ],
  "lastModified": "2026-06-17T01:49:36.213",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:powermonitor_1000_firmware:1408-em3a-ent_b:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "73FFE2E3-BE25-4924-8C6D-F2F32CE7D506"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:powermonitor_1000:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "882E9A4B-4CBB-40B5-B411-CDF3C33B1156"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}