CVE-2018-18981

High (7.5)—
Schedule the patchSeverity High 7.5. No public exploit or active exploitation known.
Severity7.5High · CVSS 3.0
Exploitation probability3.87 %higher than 91% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 05:00 PM
Public exploitNot knownno public code found

In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services.

Timeline

Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.

  1. CVE record published in NVD
  2. Record last modified in NVD

Affected technologies (1)

NVD record

NVD status
Modified
Published
Jan 24, 2019
Last modified
Jun 16, 2026
CVSS vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness (CWE)
CWE-122, CWE-787

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2018-18981",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 6.9,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "Rockwell",
          "product": "Rockwell Automation FactoryTalk Services Platform v2.90 and earlier",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation FactoryTalk Services Platform v2.90 and earlier"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-01-24T21:29:00.307",
  "references": [
    {
      "url": "http://www.securityfocus.com/bid/106279",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-331-02",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.securityfocus.com/bid/106279",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-331-02",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services."
    },
    {
      "lang": "es",
      "value": "En Rockwell Automation FactoryTalk Services Platform 2.90 y anteriores, un atacante remoto no autenticado podría enviar numerosos paquetes manipulados a los puertos de servicio, lo que resulta en una corrupción de memoria que podría desembocar en una condición de denegación de servicio (DoS) parcial o completa de los servicios afectados."
    }
  ],
  "lastModified": "2026-06-17T01:48:12.857",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CEA7A7A0-D5C4-420E-955A-D299AFEBABC5",
              "versionEndIncluding": "2.90"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}