« Volver al listado

CVE-2018-18255

Estado: ModificadaAlta (7.8)—

An issue was discovered in CapMon Access Manager 5.4.1.1005. The client applications of AccessManagerCoreService.exe communicate with this server through named pipes. A user can initiate communication with the server by creating a named pipe and sending commands to achieve elevated privileges.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-18255",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.2,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-03-15T15:29:00.520",
  "references": [
    {
      "url": "https://improsec.com/tech-blog/cam1",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://improsec.com/tech-blog/cam1",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in CapMon Access Manager 5.4.1.1005. The client applications of AccessManagerCoreService.exe communicate with this server through named pipes. A user can initiate communication with the server by creating a named pipe and sending commands to achieve elevated privileges."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en CapMon Access Manager 5.4.1.1005. Las aplicaciones de cliente de AccessManagerCoreService.exe se comunican con este servidor mediante tuberías nombradas. Un usuario puede iniciar comunicaciones con el servidor creando una tubería nombrada y enviando comandos para lograr elevar privilegios."
    }
  ],
  "lastModified": "2026-06-17T01:46:54.233",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:capmon:access_manager:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "28C7571C-6E5E-4D68-A976-733275153FC0",
              "versionEndIncluding": "5.4.1.1005"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}