CVE-2018-17924
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
- Puntuación base: 8.6
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 4.33%
- Percentil entre todas las CVEs puntuadas: 91
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (16)
CWE
- CWE-306
- CWE-306
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-17924",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2018-17924",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-06-03T13:43:29.500837Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 8.6,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 4,
"exploitabilityScore": 3.9
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "MicroLogix 1400 Controllers Series A, all versions, Series B, v21.003 and earlier,Series C, v21.003 and earlier, 1756 ControlLogix EtherNet/IP Communications Modules 1756-ENBT, all versions, 1756-EWEB Series A, all versions Series B, all versions, 1756-EN2F Series A, all versions, Series B, all versions, Series C, v10.10 and earlier, 1756-EN2T, Series A, all versions, Series B, all versions, Series C, all versions, Series D, v10.10 and earlier, 1756-EN2TR, Series A, all versions, Series B, all versions, Series C, v10.10 and earlier, 1756-EN3TR, Series A, all versions, Series B, v10.10 and earlier."
}
]
}
]
}
],
"published": "2018-12-07T14:29:00.663",
"references": [
{
"url": "http://www.securityfocus.com/bid/106132",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-310-02",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/106132",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-310-02",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address."
},
{
"lang": "es",
"value": "Rockwell Automation MicroLogix 1400 Controllers y 1756 ControlLogix Communications Modules. Un actor de amenaza remoto no autenticado podría enviar una petición de conexión CIP a un dispositivo afectado y, tras conectarse exitosamente, enviar una nueva configuración IP al dispositivo afectado incluso aunque el controlador en el sistema esté configurado en modo Hard RUN. Cuando el dispositivo afectado acepta esta nueva configuración IP, ocurre una pérdida de comunicación entre el dispositivo y el resto del sistema, ya que el tráfico del sistema sigue intentando comunicarse con el dispositivo mediante la dirección IP sobrescrita."
}
],
"lastModified": "2026-06-17T01:46:32.423",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "11507EFF-5C53-4217-9257-21936118C032"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "196EA0BE-FDF3-46BE-B3DA-5F49208C5D80"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-enbt_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "321698DF-C035-45A7-84A7-503C9162330F"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-enbt:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "330E9A05-C869-41B1-BB28-FD2A7C7ED0CE"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-eweb_series_a_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A8B22952-CE7C-4324-BF4D-61131FE4B253"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-eweb_series_a:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "045500B9-F371-4D33-9621-3E978606752D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-eweb_series_b_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5153E2F2-FC41-4BF0-B625-EA50C55A5329"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-eweb_series_b:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E4C4FF18-B699-4313-B504-F9C75816B512"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2f_series_a_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0D4B3185-B776-46C4-B47F-CE48861A422B"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2f_series_a:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "97AC710F-97B3-47A1-86EC-3148A21F16B2"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2f_series_b_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7242493E-0B2A-4AF3-BF44-15D3D1DB0021"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2f_series_b:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FA49358A-F76E-4DEC-994C-B988DE38BF7F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2f_series_c_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "42555C87-3D2A-460F-85A4-626410C56731",
"versionEndIncluding": "10.10"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2f_series_c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C6E5B08F-BD0C-4B3F-9897-61C945981CC6"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2t_series_a_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B8E9CEA5-F039-484D-A234-1E3ADA352E32"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2t_series_a:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "BBB6A3C1-6419-4CDB-B7F5-57F20DA43C5A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2t_series_b_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "ADCF431D-0F13-4037-BBDF-4199B5860CCA"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2t_series_b:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5E9D2541-B0DB-4925-ACD6-FCC2A028FA4A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2t_series_c_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E9B8DEC1-3980-49E0-82B1-275FD7870EC9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2t_series_c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "13581B79-89FF-42F0-93C1-CB77582E7303"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2t_series_d_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8BC034DA-D8ED-43CA-9D7B-2592B58BC0F4",
"versionEndIncluding": "10.10"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2t_series_d:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F71090C1-36AD-4A1B-92B5-CB391593DF4B"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2tr_series_a_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "94271569-D658-4F95-B9A6-2C1DB2647EB2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2tr_series_a:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A4A8E21A-3826-497C-9F3D-6D9091AD7647"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2tr_series_b_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BAEF2D94-6224-4877-9169-E5B0DB3FAA25"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2tr_series_b:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8607CD0D-0EE7-41CF-8E00-C0F5C83646A8"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2tr_series_c_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "99562089-73F5-4AF9-BEE6-E7B977678AAD",
"versionEndIncluding": "10.10"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2tr_series_c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D58BA41B-3859-4489-9C74-730C27B1EFF0"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en3tr_series_a_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EE90B141-E680-4D15-8BCE-8D58909A3679"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en3tr_series_a:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4824C266-82B1-4B74-AF72-BFCEF0547023"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en3tr_series_b_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3493D13F-CC5F-470D-ADFE-79C2C90665D6",
"versionEndIncluding": "10.10"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en3tr_series_b:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "14CF3A11-7130-420A-B99E-8FADA7C23484"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}