« Volver al listado

CVE-2018-17066

Estado: ModificadaCrítica (9.8)—

An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction in the handler function of the /goform/form2systime.cgi route. This could lead to command injection via shell metacharacters in the datetime parameter.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-17066",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 10,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-09-15T21:29:00.647",
  "references": [
    {
      "url": "https://github.com/PAGalaxyLab/VulInfo/tree/master/D-Link/DIR-816/cmd_injection_0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/PAGalaxyLab/VulInfo/tree/master/D-Link/DIR-816/cmd_injection_0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction in the handler function of the /goform/form2systime.cgi route. This could lead to command injection via shell metacharacters in the datetime parameter."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos D-Link DIR-816 A2 1.10 B05. Se emplea un parámetro de petición HTTP en la construcción de cadenas de comandos en la función handler de la ruta  goform form2systime.cgi. Esto podría conducir a la inyección de comandos mediante metacaracteres shell en el parámetro datetime."
    }
  ],
  "lastModified": "2026-06-17T01:45:18.493",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-816_a2_firmware:1.10_b05:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "136103D2-0066-4B79-8D96-23001406B722"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-816_a2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "DE0BF6D7-F3B3-4E25-807B-21055E5887CE"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}