CVE-2018-16193
Estado: ModificadaMedia (5.4)—
Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
- Puntuación base: 5.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.53%
- Percentil entre todas las CVEs puntuadas: 43
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-16193",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 3.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 5.4,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.3
}
]
},
"affected": [
{
"source": "vultures@jpcert.or.jp",
"affectedData": [
{
"vendor": "NEC Corporation",
"product": "Aterm WF1200CR and Aterm WG1200CR",
"versions": [
{
"status": "affected",
"version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
}
]
}
]
}
],
"published": "2019-01-09T23:29:04.403",
"references": [
{
"url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
"tags": [
"Vendor Advisory"
],
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://jvn.jp/en/jp/JVN87535892/index.html",
"tags": [
"Third Party Advisory"
],
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://jvn.jp/en/jp/JVN87535892/index.html",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
},
{
"lang": "es",
"value": "Vulnerabilidad Cross-Site Scripting (XSS) en Aterm WF1200CR y Aterm WG1200CR (Aterm WF1200CR con firmware en versiones 1.1.1 y anteriores y Aterm WG1200CR con firmware en versiones 1.0.1 y anteriores) permite que los atacantes autenticados inyecten scripts web o HTML arbitrarios mediante vectores sin especificar."
}
],
"lastModified": "2026-06-17T01:43:51.963",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nec:aterm_wf1200cr_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "076240BB-05FD-49BF-B009-AEA6EEF83578",
"versionEndIncluding": "1.1.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nec:aterm_wf1200cr:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "3A91D9EB-5962-498E-9B14-C5712DDDF7C2"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nec:aterm_wg1200cr_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F4C4E131-9306-4F48-A658-CA823B6E65ED",
"versionEndIncluding": "1.0.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nec:aterm_wg1200cr:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "936D9DD3-11E5-4862-B157-85B13EA06C38"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp"
}