« Volver al listado

CVE-2018-14866

Estado: ModificadaMedia (4.3)—

Incorrect access control in the TransientModel framework in Odoo Community 11.0 and earlier and Odoo Enterprise 11.0 and earlier allows authenticated attackers to access data in transient records that they do not own by making an RPC call before garbage collection occurs.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-14866",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
          "authentication": "SINGLE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-07-03T18:15:10.317",
  "references": [
    {
      "url": "https://github.com/odoo/odoo/issues/32509",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/odoo/odoo/issues/32509",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Incorrect access control in the TransientModel framework in Odoo Community 11.0 and earlier and Odoo Enterprise 11.0 and earlier allows authenticated attackers to access data in transient records that they do not own by making an RPC call before garbage collection occurs."
    },
    {
      "lang": "es",
      "value": "El control de acceso incorrecto en el marco de TransientModel en Odoo Community 11.0 y versiones anteriores y Odoo Enterprise 11.0 y versiones anteriores permite que los atacantes identificados accedan a datos en registros transitorios que no poseen al realizar una llamada RPC antes de que se produzca la recolección de basura."
    }
  ],
  "lastModified": "2026-06-17T01:41:47.313",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:odoo:odoo:9.0:*:*:*:community:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C3F9E8F1-FAF7-44AE-8D05-BE717D247EDE"
            },
            {
              "criteria": "cpe:2.3:a:odoo:odoo:9.0:*:*:*:enterprise:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "167C709E-C8B2-4CCB-963E-E1D8C664190A"
            },
            {
              "criteria": "cpe:2.3:a:odoo:odoo:10.0:*:*:*:community:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C52F2EEB-11E5-49E8-AD06-3014FF2C2D24"
            },
            {
              "criteria": "cpe:2.3:a:odoo:odoo:10.0:*:*:*:enterprise:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A4405E54-6C16-49D5-B632-3D72091B2FEB"
            },
            {
              "criteria": "cpe:2.3:a:odoo:odoo:11.0:*:*:*:community:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "38424B03-4121-4A79-8E4E-4CB4DCD3E4A5"
            },
            {
              "criteria": "cpe:2.3:a:odoo:odoo:11.0:*:*:*:enterprise:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1298CF62-A06E-48AD-8141-0541DE3F6381"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}