CVE-2018-14821
High (7.5)—
Severity7.5High · CVSS 3.0
Exploitation probability4.50 %higher than 92% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 05:00 PM
Public exploitNot knownno public code found
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality.
Timeline
Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.
- CVE record published in NVD
- Record last modified in NVD
Affected technologies (1)
NVD record
- NVD status
- Modified
- Published
- Sep 20, 2018
- Last modified
- Jun 16, 2026
- CVSS vector
- CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Weakness (CWE)
- CWE-122, CWE-119
References
- Government advisoryics-cert.us-cert.gov/advisories/ICSA-18-263-02
- Third-party advisorytenable.com/security/research/tra-2018-26
Raw JSON (NVD)
Show
{
"id": "CVE-2018-14821",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "RSLinx Classic",
"versions": [
{
"status": "affected",
"version": "4.00.01 and prior"
}
]
}
]
}
],
"published": "2018-09-20T19:29:00.470",
"references": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.tenable.com/security/research/tra-2018-26",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.tenable.com/security/research/tra-2018-26",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-122"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality."
},
{
"lang": "es",
"value": "Rockwell Automation RSLinx Classic en versiones 4.00.01 y anteriores. Esta vulnerabilidad podría permitir que un actor de amenaza remoto no autenticado envíe de forma intencional un paquete CIP mal formado al puerto 44818, lo que provoca que la aplicación RSLinx Classic se termine. El usuario necesitará reiniciar manualmente el software para recuperar la funcionalidad."
}
],
"lastModified": "2026-06-17T01:41:42.527",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx:*:*:*:*:classic:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8A2F3687-1906-476D-9947-B4A02AAA1E24",
"versionEndIncluding": "4.00.01"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}