CVE-2017-9829
Status: ModifiedHigh (7.5)—
'/cgi-bin/admin/downloadMedias.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable, which allows remote attackers to read any file on the camera's Linux filesystem via a crafted HTTP request containing ".." sequences. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected.
CVSS
- Version: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Base score: 7.5
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 69%
- Percentile among all scored CVEs: 99
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (3)
CWEs
- CWE-22
References
Raw JSON (NVD)
Show
{
"id": "CVE-2017-9829",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2017-06-23T22:29:00.210",
"references": [
{
"url": "https://blog.cal1.cn/post/An%20easy%20way%20to%20pwn%20most%20of%20the%20vivotek%20network%20cameras",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://blog.cal1.cn/post/An%20easy%20way%20to%20pwn%20most%20of%20the%20vivotek%20network%20cameras",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "'/cgi-bin/admin/downloadMedias.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable, which allows remote attackers to read any file on the camera's Linux filesystem via a crafted HTTP request containing \"..\" sequences. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected."
},
{
"lang": "es",
"value": "'/cgi-bin/admin/downloadMedias.cgi' del servicio web en la mayoría de las VIVOTEK Network Cameras es vulnerable, lo que permite a un atacante remoto leer cualquier archivo del sistema de ficheros Linux de las cámaras mediante una solicitud HTTP manipulada que contenga secuencias \"..\". Esta vulnerabilidad ya esta verificada en VIVOTEK Network Camera IB8369/FD8164/FD816BA; muchas de la otras tienen un firmware similar que también puede ser afectado."
}
],
"lastModified": "2026-06-17T01:29:00.070",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vivotek:network_camera_ib8369_firmware:ib8369-vvtk-0102a:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "02C5DB13-2631-42A1-9D33-109626D9B2AA"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vivotek:network_camera_ib8369:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2CED8977-65CE-47C7-B62D-D604429BF3DF"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vivotek:network_camera_fd8164_firmware:fd8164-_vvtk-0200b:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BEDC585B-65BF-4A18-96A3-440A45B5527B"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vivotek:network_camera_fd8164:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "62D8DD51-8504-493F-A8A2-D260D785903E"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vivotek:network_camera_fd816ba_firmware:fd816ba-vvtk-010101.:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A8E8D766-0F98-4FDB-95AA-C48B5991DED5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vivotek:network_camera_fd816ba:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5C83867F-EEC1-4C38-90F7-FB32DAB32455"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}