« Back to list

CVE-2017-9828

Status: ModifiedCritical (9.8)—

'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root via a crafted HTTP request. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. An attack uses shell metacharacters in the senderemail parameter.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (3)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2017-9828",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 10,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2017-06-23T22:29:00.163",
  "references": [
    {
      "url": "https://blog.cal1.cn/post/An%20easy%20way%20to%20pwn%20most%20of%20the%20vivotek%20network%20cameras",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://blog.cal1.cn/post/An%20easy%20way%20to%20pwn%20most%20of%20the%20vivotek%20network%20cameras",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root via a crafted HTTP request. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. An attack uses shell metacharacters in the senderemail parameter."
    },
    {
      "lang": "es",
      "value": "'/cgi-bin/admin/testserver.cgi' del servicio web en la mayoría de las VIVOTEK Network Cameras es vulnerable a la inyección de un comando shell, lo que permite a un atacante remoto ejecutar cualquier comando shell como si fuera root mediante una solicitud HTTP manipulada. Esta vulnerabilidad ya esta verificada en VIVOTEK Network Camera IB8369/FD8164/FD816BA; muchas de las otras tienen un firmware similar que puede ser afectado. Un ataque usa metacaracteres shell en el parámetro sendremail."
    }
  ],
  "lastModified": "2026-06-17T01:28:59.900",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:vivotek:network_camera_ib8369_firmware:ib8369-vvtk-0102a:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "02C5DB13-2631-42A1-9D33-109626D9B2AA"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:vivotek:network_camera_ib8369:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2CED8977-65CE-47C7-B62D-D604429BF3DF"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:vivotek:network_camera_fd8164_firmware:fd8164-_vvtk-0200b:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BEDC585B-65BF-4A18-96A3-440A45B5527B"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:vivotek:network_camera_fd8164:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "62D8DD51-8504-493F-A8A2-D260D785903E"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:vivotek:network_camera_fd816ba_firmware:fd816ba-vvtk-010101.:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A8E8D766-0F98-4FDB-95AA-C48B5991DED5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:vivotek:network_camera_fd816ba:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "5C83867F-EEC1-4C38-90F7-FB32DAB32455"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}