Estado: ModificadaMedia (5.9)—

A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2017-6024",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.1,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 6.9,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.2
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380"
            }
          ]
        }
      ]
    }
  ],
  "published": "2017-05-06T00:29:00.163",
  "references": [
    {
      "url": "http://www.securityfocus.com/bid/98309",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.securityfocus.com/bid/98309",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema de agotamiento de recursos en Rockwell Automation ControlLogix 5580 en los controladores V28.011, V28.012 y V28.013."
    }
  ],
  "lastModified": "2026-06-17T01:21:38.863",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:v28.011:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8DEA0815-1269-4B24-B7D5-5B5BE06B8E43"
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:v29.011:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "771314D1-C8A2-4A9F-A4AB-24C767BB48DA"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:v28.011:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "489DD270-EBC9-4848-BE4C-4FB2D1786521"
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:v28.012:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FEAFDB5D-4B06-47D4-96D6-BF24FEEA0749"
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:v28.013:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6F8BC8FB-B3E9-43CB-B8C6-807DCBC0204C"
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:v29.011:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1D073C02-AE97-4D14-9682-84B42D0FBDA5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}