CVE-2017-5157

Medium (6.1)—
Routine follow-upSeverity Medium 6.1. No public exploit or active exploitation known.
Severity6.1Medium · CVSS 3.0
Exploitation probability1.46 %higher than 74% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 05:00 PM
Public exploitNot knownno public code found

An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.

Timeline

Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.

  1. CVE record published in NVD
  2. Record last modified in NVD

Affected technologies (1)

NVD record

NVD status
Modified
Published
Feb 13, 2017
Last modified
Jun 16, 2026
CVSS vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Weakness (CWE)
CWE-79

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2017-5157",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Schneider Electric homeLYnk Controller prior to V1.5.0",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric homeLYnk Controller prior to V1.5.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2017-02-13T21:59:02.767",
  "references": [
    {
      "url": "http://www.securityfocus.com/bid/95665",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-019-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.securityfocus.com/bid/95665",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-019-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code."
    },
    {
      "lang": "es",
      "value": "Ha sido descubierto un problema en Schneider Electric homeLYnk Controller, LSS100100, todas las versiones anteriores a V1.5.0. El controlador homeLYnk es susceptible a un ataque de secuencias de comandos en sitios cruzados. Las entradas del usuario pueden ser manipuladas para provocar la ejecución de código JavaScript."
    }
  ],
  "lastModified": "2026-06-17T01:20:03.953",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider_electric:homelynk_controller_lss100100_firmware:1.3.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5D235123-C722-4B40-9A0A-6BB40A2FF180"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:homelynk_controller_lss100100:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "69F69759-DDB2-4831-8E88-0D40BD9E7AE5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}