CVE-2017-4984
Estado: ModificadaCrítica (9.8)—
In EMC VNX2 versions prior to OE for File 8.1.9.211 and VNX1 versions prior to OE for File 7.1.80.8, an unauthenticated remote attacker may be able to elevate their permissions to root through a command injection. This may potentially be exploited by an attacker to run arbitrary code with root-level privileges on the targeted VNX Control Station system, aka remote code execution.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 6.57%
- Percentil entre todas las CVEs puntuadas: 94
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-77
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-4984",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 10,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": true,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "security_alert@emc.com",
"affectedData": [
{
"vendor": "n/a",
"product": "EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8",
"versions": [
{
"status": "affected",
"version": "EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8"
}
]
}
]
}
],
"published": "2017-06-19T12:29:00.230",
"references": [
{
"url": "http://www.securityfocus.com/archive/1/540738/30/0/threaded",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "security_alert@emc.com"
},
{
"url": "http://www.securityfocus.com/bid/99039",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "security_alert@emc.com"
},
{
"url": "http://www.securityfocus.com/archive/1/540738/30/0/threaded",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/99039",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In EMC VNX2 versions prior to OE for File 8.1.9.211 and VNX1 versions prior to OE for File 7.1.80.8, an unauthenticated remote attacker may be able to elevate their permissions to root through a command injection. This may potentially be exploited by an attacker to run arbitrary code with root-level privileges on the targeted VNX Control Station system, aka remote code execution."
},
{
"lang": "es",
"value": "En EMC VNX2 en versiones anteriores a OE for File 8.1.9.211 y VNX1 en versiones anteriores a OE for File 7.1.80.8, un atacante remoto no autenticado podría ser capaz de elevar sus privilegios a root mediante una inyección de comandos. Esto podría ser explotado por un atacante para ejecutar código arbitrario con privilegios de nivel root en el sistema VNX Control Station objetivo. Esto también se conoce como ejecución remota de código."
}
],
"lastModified": "2026-06-17T01:19:41.110",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:emc:vnx2_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F1DC2941-60A4-4232-AB6C-B5C3F5E0A034"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:emc:vnx2:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CA171162-0FF7-43B3-A5D4-9C954E5B37D6"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:emc:vnx1_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A4EE4E75-2B7D-4826-BFD8-84739A554316"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:emc:vnx1:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5C707E8E-AC08-4B58-9AA1-2850A8BC94F8"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "security_alert@emc.com"
}