CVE-2017-2685
Estado: ModificadaAlta (7.4)—
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
- Puntuación base: 7.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.97%
- Percentil entre todas las CVEs puntuadas: 61
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-693
- CWE-200
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-2685",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 4.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.4,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "n/a",
"product": "SINUMERIK Integrate Operate Clients 2.x and 3.x",
"versions": [
{
"status": "affected",
"version": "SINUMERIK Integrate Operate Clients 2.x and 3.x"
}
]
}
]
}
],
"published": "2017-03-01T17:59:00.143",
"references": [
{
"url": "http://www.securityfocus.com/bid/96519",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "productcert@siemens.com"
},
{
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-934525.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "http://www.securityfocus.com/bid/96519",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-934525.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-693"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack."
},
{
"lang": "es",
"value": "Siemens SenUMERIK entegrate Operate Clients en versiones entre 2.0.3.00.016 (incluida) y 2.0.6 (excluida) y en versiones entre 3.0.4.00.032 (incluida) y 3.0.6 (excluida) contienen una vulnerabilidad que podría permitir a un atacante leer y manipular datos en sesiones TLS cuando interpreta un ataque a man-in-the-middle (MITM)"
}
],
"lastModified": "2026-06-17T01:16:39.877",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinumerik_integrate_access_mymachine\\/ethernet:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "ECD7B773-A606-404F-A7A2-C78650CD2571"
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_integrate_operate_client:2.0.3.00.016:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "679949AD-5709-4393-8E3C-3370C8450EB9"
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_integrate_operate_client:3.0.4.00.032:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7E3D02F5-B1DE-457F-9F55-F1B8B8A2A20D"
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_operate:4.5:sp6:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C0BE905B-E687-4CE4-9BF3-89B670D8EE6B"
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_operate:4.7:sp2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "80D41351-0B3D-40E3-90C0-B7D30934F47C"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}