CVE-2017-20238
Hirschmann Industrial HiVision versions 06.0.00 and 07.0.00 prior to 06.0.06 and 07.0.01 contains an improper authorization vulnerability that allows read-only users to gain write access to managed devices by bypassing access control mechanisms. Attackers can exploit alternative interfaces such as the web interface or SNMP browser to modify device configurations despite having restricted permissions.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.24%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1565.001Stored Data Manipulationimpact80 % - Impacto secundario
T1548.001Setuid and Setgidprivilege escalation75 %
Vulnerabilidad de autorización (CWE-285) en servicio remoto (AV:N, PR:L) que permite a usuarios de solo lectura modificar configuraciones de dispositivos gestionados mediante interfaces alternativas como SNMP, escalando privilegios de escritura.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-285
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-20238",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2017-20238",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-04-06T17:53:15.454274Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 4.2,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "disclosure@vulncheck.com",
"affectedData": [
{
"vendor": "Belden",
"product": "Hirschmann Industrial HiVision",
"versions": [
{
"status": "unaffected",
"version": "06.0.06",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "07.0.01",
"versionType": "custom"
},
{
"status": "affected",
"version": "06.0.00",
"versionType": "custom",
"lessThanOrEqual": "06.0.05"
},
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "07.00"
}
],
"defaultStatus": "affected"
}
]
}
],
"published": "2026-04-03T23:17:00.633",
"references": [
{
"url": "https://assets.belden.com/m/7cc5d59343125b25/original/Security-Bulletin-Restricted-User-Roles-Write-Access-HiVision-2017-01.pdf",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.vulncheck.com/advisories/hirschmann-industrial-hivision-improper-authorization-privilege-escalation",
"source": "disclosure@vulncheck.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"description": [
{
"lang": "en",
"value": "CWE-285"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Hirschmann Industrial HiVision versions 06.0.00 and 07.0.00 prior to 06.0.06 and 07.0.01 contains an improper authorization vulnerability that allows read-only users to gain write access to managed devices by bypassing access control mechanisms. Attackers can exploit alternative interfaces such as the web interface or SNMP browser to modify device configurations despite having restricted permissions."
},
{
"lang": "es",
"value": "Las versiones 06.0.00 y 07.0.00 de Hirschmann Industrial HiVision anteriores a la 06.0.06 y 07.0.01 contienen una vulnerabilidad de autorización inapropiada que permite a los usuarios de solo lectura obtener acceso de escritura a los dispositivos gestionados al eludir los mecanismos de control de acceso. Los atacantes pueden explotar interfaces alternativas, como la interfaz web o el navegador SNMP, para modificar las configuraciones de los dispositivos a pesar de tener permisos restringidos."
}
],
"lastModified": "2026-07-21T07:10:00.117",
"sourceIdentifier": "disclosure@vulncheck.com"
}