CVE-2017-18773
Status: ModifiedMedium (6.7)—
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before V1.0.0.55, D7800 before V1.0.1.24, EX6150v2 before 1.0.0.48, R6100 before 1.0.1.14, R7500 before 1.0.0.110, R7500v2 before V1.0.3.16, R7800 before V1.0.2.36, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.48.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Base score: 6.7
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.56%
- Percentile among all scored CVEs: 44
- Score date: 10/5/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (9)
CWEs
- CWE-74
References
Raw JSON (NVD)
Show
{
"id": "CVE-2017-18773",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.6,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 6.7,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.8
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.7,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-04-22T15:15:11.863",
"references": [
{
"url": "https://kb.netgear.com/000049556/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2184",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://kb.netgear.com/000049556/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2184",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-74"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before V1.0.0.55, D7800 before V1.0.1.24, EX6150v2 before 1.0.0.48, R6100 before 1.0.1.14, R7500 before 1.0.0.110, R7500v2 before V1.0.3.16, R7800 before V1.0.2.36, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.48."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR están afectados por una inyección de comandos por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a V1.0.0.55, D7800 versiones anteriores a V1.0.1.24, EX6150v2 versiones anteriores a 1.0.0.48, R6100 versiones anteriores a 1.0.1.14, R7500 versiones anteriores a 1.0.0.110, R7500v2 versiones anteriores a V1.0.3.16, R7800 versiones anteriores a V1.0.2. 36, WNDR4300v1 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.48."
}
],
"lastModified": "2026-06-17T01:13:31.647",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A37AA7DC-5B2C-4E1B-8556-F1C9F6BBE9D7",
"versionEndExcluding": "1.0.0.55"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F3197737-90A5-411B-8F3D-902D7FD3CEB6",
"versionEndExcluding": "1.0.1.24"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9984CEE5-F523-4546-AEAD-4361D2BC6D2B",
"versionEndExcluding": "1.0.0.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7E8197CA-84A2-4714-8EBB-04BA4B66ED29",
"versionEndExcluding": "1.0.1.14"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7F227D99-88C9-457F-BCA5-665F531E04AB",
"versionEndExcluding": "1.0.0.110"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1F587C0F-5A9A-468B-B680-21EB9700DD4B",
"versionEndExcluding": "1.0.3.16"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74",
"versionEndExcluding": "1.0.2.36"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6",
"versionEndExcluding": "1.0.2.90"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0",
"versionEndExcluding": "1.0.0.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A",
"versionEndExcluding": "1.0.0.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3C8BF9E6-5EEB-48A3-BF23-30FFB78F339A",
"versionEndExcluding": "1.0.0.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}