« Back to list

CVE-2017-16281

Status: ModifiedCritical (9.9)—

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_net, at 0x9d018234, the value for the `sub` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2017-16281",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2017-16281",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-08T17:51:44.479858Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "talos-cna@cisco.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 8.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.8
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.9,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.1
      }
    ]
  },
  "affected": [
    {
      "source": "talos-cna@cisco.com",
      "affectedData": [
        {
          "vendor": "Insteon",
          "product": "Hub",
          "versions": [
            {
              "status": "affected",
              "version": "Not specified"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-01-11T22:15:11.387",
  "references": [
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0483",
      "tags": [
        "Technical Description",
        "Third Party Advisory"
      ],
      "source": "talos-cna@cisco.com"
    },
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0483",
      "tags": [
        "Technical Description",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "talos-cna@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the \"cc\" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_net, at 0x9d018234, the value for the `sub` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow."
    },
    {
      "lang": "es",
      "value": "Existen múltiples vulnerabilidades de desbordamiento de búfer explotables en el controlador de mensajes PubNub para el canal \"cc\" de Insteon Hub que ejecuta la versión de firmware 1012. Los comandos especialmente manipulados enviados a través del servicio PubNub pueden provocar un desbordamiento de búfer en la región stack de la memoria que sobrescriba datos arbitrarios. Un atacante debería enviar una solicitud HTTP autenticada para activar esta vulnerabilidad. En cmd s_net, en 0x9d018234, el valor de la clave `sub` se copia usando `strcpy` al búfer en `$sp+0x2b0`. Este búfer tiene 32 bytes de tamaño, enviar algo más largo provocará un desbordamiento del búfer."
    }
  ],
  "lastModified": "2026-06-17T01:09:05.897",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insteon:hub_firmware:1012:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "17F98B37-72C0-48A5-A4E2-12327F48327E"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:insteon:hub:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "951165BE-0AC1-4690-8B36-E402CA0197FB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com"
}