CVE-2017-12785
Estado: ModificadaCrítica (9.8)—
The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 16%
- Percentil entre todas las CVEs puntuadas: 97
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-119
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-12785",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 10,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": true,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2017-08-22T17:29:00.193",
"references": [
{
"url": "https://www.exploit-db.com/exploits/42518/",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.exploit-db.com/exploits/42518/",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the \"show log cli\" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection."
},
{
"lang": "es",
"value": "La interfaz de línea de comandos de novish, incluida en la distribución de software NoviWare en su versión NW400.2.6 e implementada en dispositivos NoviSwitch tiene tendencia a sufrir un desbordamiento de búfer en el comando \"show log cli\". Esto podría ser empleado por un usuario con permisos de sólo lectura (rol de monitorización) para obtener privilegios (root) de ejecución de código en el switch mediante la inyección de comandos."
}
],
"lastModified": "2026-06-17T01:03:55.887",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:noviflow:noviware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "69810F5C-5FAF-48E8-A481-FA3EF0AFBE59",
"versionEndIncluding": "400.2.6"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}