CVE-2017-12721
Estado: ModificadaMedia (5.9)—
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 5.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.67%
- Percentil entre todas las CVEs puntuadas: 51
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-295
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-12721",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 5.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump",
"versions": [
{
"status": "affected",
"version": "Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump"
}
]
}
]
}
],
"published": "2018-02-15T10:29:00.320",
"references": [
{
"url": "http://www.securityfocus.com/bid/100665",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02A",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/100665",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02A",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-295"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack."
},
{
"lang": "es",
"value": "Se ha descubierto un problema de validación de certificados incorrecta en Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, en versiones 1.1, 1.5 y 1.6. La bomba no valida los certificados del host, lo que hace que la bomba sea vulnerable a ataques Man-in-the-Middle (MitM)."
}
],
"lastModified": "2026-06-17T01:03:50.587",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E9DB2BFA-A772-4A90-B79B-D6FB2090A63C"
},
{
"criteria": "cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.5:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AC867D0F-2FF0-4E99-87FF-84A873F56341"
},
{
"criteria": "cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.6:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "048B188C-D620-42EE-84D5-61C3F03F7FAA"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9874E6FE-4025-484B-A7D4-62824A299ECA"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}