« Volver al listado

CVE-2017-12573

Estado: ModificadaAlta (8.8)—

An issue was discovered on PLANEX CS-W50HD devices with firmware before 030720. The device has a command-injection vulnerability in the web management UI on NAS settings page "/cgi-bin/nasset.cgi". An attacker can send a crafted HTTP POST request to execute arbitrary code. Authentication is required before executing the attack.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2017-12573",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "authentication": "SINGLE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-08-24T19:29:00.533",
  "references": [
    {
      "url": "http://seclists.org/fulldisclosure/2018/Aug/29",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://seclists.org/fulldisclosure/2018/Aug/29",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on PLANEX CS-W50HD devices with firmware before 030720. The device has a command-injection vulnerability in the web management UI on NAS settings page \"/cgi-bin/nasset.cgi\". An attacker can send a crafted HTTP POST request to execute arbitrary code. Authentication is required before executing the attack."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en los dispositivos PLANEX CS-W50HD con firmware en versiones anteriores a la 030720. El dispositivo tiene una vulnerabilidad de inyección de comandos en la interfaz de usuario de gestión web en la página de opciones NAS \"/cgi-bin/nasset.cgi\". Un atacante puede enviar una petición HTTP POST manipulada para ejecutar código arbitrario. Se requiere autenticación antes de ejecutar el ataque."
    }
  ],
  "lastModified": "2026-06-17T01:03:31.620",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:planex:cs-w50hd_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "90E29744-0045-45BB-9F8D-E770733018AC",
              "versionEndExcluding": "030720"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:planex:cs-w50hd:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C94DCF20-56F6-4D91-817A-EC033CAAAE1C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}