CVE-2017-12093
Medium (5.3)—
Severity5.3Medium · CVSS 3.1
Exploitation probability6.00 %higher than 94% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 05:00 PM
Public exploitNot knownno public code found
An exploitable insufficient resource pool vulnerability exists in the session communication functionality of Allen Bradley Micrologix 1400 Series B Firmware 21.2 and before. A specially crafted stream of packets can cause a flood of the session resource pool resulting in legitimate connections to the PLC being disconnected. An attacker can send unauthenticated packets to trigger this vulnerability.
Timeline
Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.
- CVE record published in NVD
- Record last modified in NVD
Affected technologies (1)
NVD record
- NVD status
- Modified
- Published
- Apr 5, 2018
- Last modified
- Jun 16, 2026
- CVSS vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
- Weakness (CWE)
- CWE-400
References
- Third-party advisorytalosintelligence.com/vulnerability_reports/TALOS-2017-0445
Raw JSON (NVD)
Show
{
"id": "CVE-2017-12093",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "talos-cna@cisco.com",
"affectedData": [
{
"vendor": "Talos",
"product": "Allen Bradley",
"versions": [
{
"status": "affected",
"version": "Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15"
}
]
}
]
}
],
"published": "2018-04-05T21:29:00.460",
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0445",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "talos-cna@cisco.com"
},
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0445",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An exploitable insufficient resource pool vulnerability exists in the session communication functionality of Allen Bradley Micrologix 1400 Series B Firmware 21.2 and before. A specially crafted stream of packets can cause a flood of the session resource pool resulting in legitimate connections to the PLC being disconnected. An attacker can send unauthenticated packets to trigger this vulnerability."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad explotable de denegación de servicio (DoS) en la funcionalidad de comunicación de sesión de Allen Bradley Micrologix 1400 Series B Firmware, en versiones 21.2 y anteriores. Un flujo de paquetes especialmente manipulado puede provocar la inundación del pool de recursos de sesión que resulta en conexiones legítimas al PCL que se está desconectando. Un atacante puede enviar paquetes sin autenticación para provocar esta vulnerabilidad."
}
],
"lastModified": "2026-06-17T01:02:40.200",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400_b_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E3CFD00A-A73C-46AA-B6BD-93C44FBCC98F",
"versionEndIncluding": "21.2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "196EA0BE-FDF3-46BE-B3DA-5F49208C5D80"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "talos-cna@cisco.com"
}