CVE-2017-11385
Estado: ModificadaCrítica (9.8)—
SQL Injection in Trend Micro Control Manager 6.0 causes Remote Code Execution when executing opcode 0x6b1b due to lack of proper user input validation in cmdHandlerStatusMonitor.dll. Formerly ZDI-CAN-4545.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 38%
- Percentil entre todas las CVEs puntuadas: 99
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-89
Referencias
- http://www.securityfocus.com/bid/100078
- http://www.securitytracker.com/id/1039049
- http://www.zerodayinitiative.com/advisories/ZDI-17-495
- https://success.trendmicro.com/solution/1117722
- http://www.securityfocus.com/bid/100078
- http://www.securitytracker.com/id/1039049
- http://www.zerodayinitiative.com/advisories/ZDI-17-495
- https://success.trendmicro.com/solution/1117722
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-11385",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "security@trendmicro.com",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2017-08-02T21:29:00.260",
"references": [
{
"url": "http://www.securityfocus.com/bid/100078",
"source": "security@trendmicro.com"
},
{
"url": "http://www.securitytracker.com/id/1039049",
"source": "security@trendmicro.com"
},
{
"url": "http://www.zerodayinitiative.com/advisories/ZDI-17-495",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "security@trendmicro.com"
},
{
"url": "https://success.trendmicro.com/solution/1117722",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "security@trendmicro.com"
},
{
"url": "http://www.securityfocus.com/bid/100078",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securitytracker.com/id/1039049",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.zerodayinitiative.com/advisories/ZDI-17-495",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://success.trendmicro.com/solution/1117722",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SQL Injection in Trend Micro Control Manager 6.0 causes Remote Code Execution when executing opcode 0x6b1b due to lack of proper user input validation in cmdHandlerStatusMonitor.dll. Formerly ZDI-CAN-4545."
},
{
"lang": "es",
"value": "Una vulnerabilidad de inyección SQL en Trend Micro Control Manager 6.0 permite la ejecución de código remoto cuando se ejecuta opcode 0x6b1b por no haber una validación de los datos de entrada del usuario correcta en cmdHandlerStatusMonitor.dll. Anteriormente esta vulnerabilidad tenía el código ZDI-CAN-4545."
}
],
"lastModified": "2026-06-17T01:01:43.193",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trendmicro:control_manager:6.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2F7E3779-69E4-46AB-94E3-4A81E35A5194"
}
],
"operator": "OR"
}
]
}
],