CVE-2017-11384
Estado: ModificadaCrítica (9.8)—
SQL Injection in Trend Micro Control Manager 6.0 causes Remote Code Execution when executing opcode 0x3b21 due to lack of proper user input validation in mdHandlerLicenseManager.dll. Formerly ZDI-CAN-4561.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 38%
- Percentil entre todas las CVEs puntuadas: 99
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-89
Referencias
- http://www.securityfocus.com/bid/100078
- http://www.securitytracker.com/id/1039049
- http://www.zerodayinitiative.com/advisories/ZDI-17-494
- https://success.trendmicro.com/solution/1117722
- http://www.securityfocus.com/bid/100078
- http://www.securitytracker.com/id/1039049
- http://www.zerodayinitiative.com/advisories/ZDI-17-494
- https://success.trendmicro.com/solution/1117722
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-11384",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "security@trendmicro.com",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2017-08-02T21:29:00.227",
"references": [
{
"url": "http://www.securityfocus.com/bid/100078",
"source": "security@trendmicro.com"
},
{
"url": "http://www.securitytracker.com/id/1039049",
"source": "security@trendmicro.com"
},
{
"url": "http://www.zerodayinitiative.com/advisories/ZDI-17-494",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "security@trendmicro.com"
},
{
"url": "https://success.trendmicro.com/solution/1117722",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "security@trendmicro.com"
},
{
"url": "http://www.securityfocus.com/bid/100078",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securitytracker.com/id/1039049",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.zerodayinitiative.com/advisories/ZDI-17-494",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://success.trendmicro.com/solution/1117722",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SQL Injection in Trend Micro Control Manager 6.0 causes Remote Code Execution when executing opcode 0x3b21 due to lack of proper user input validation in mdHandlerLicenseManager.dll. Formerly ZDI-CAN-4561."
},
{
"lang": "es",
"value": "Inyección SQL en Trend Micro Control Manager versión 6.0, causa una ejecución de código remota al ejecutar el código de operación 0x3b21 debido a una falta de comprobación de entrada de usuario apropiada en la biblioteca mdHandlerLicenseManager.dll. Anteriormente ZDI-CAN-4561."
}
],
"lastModified": "2026-06-17T01:01:43.093",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trendmicro:control_manager:6.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2F7E3779-69E4-46AB-94E3-4A81E35A5194"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security@trendmicro.com"
}