CVE-2017-10013
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products.
Leer descripción completaMostrar menos
Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
- Puntuación base: 8.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.86%
- Percentil entre todas las CVEs puntuadas: 79
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-10013",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2017-10013",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-10-04T15:39:59.176549Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.6,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "HIGH",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 4.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 8.3,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "secalert_us@oracle.com",
"affectedData": [
{
"vendor": "Oracle Corporation",
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
]
}
],
"published": "2017-08-08T15:29:00.600",
"references": [
{
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "secalert_us@oracle.com"
},
{
"url": "http://www.securityfocus.com/bid/99833",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "secalert_us@oracle.com"
},
{
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/99833",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
},
{
"lang": "es",
"value": "Vulnerabilidad en el componente Sun ZFS Storage Appliance Kit (AK) de Oracle Sun Systems Products Suite (subcomponente: User Interface). La versión compatible afectada es la AK 2013. Una vulnerabilidad de difícil explotación permite que un atacante sin autenticar con acceso a red por HTTP comprometa la seguridad de Sun ZFS Storage Appliance Kit (AK). Para que los ataques tengan éxito, se necesita la participación de otra persona diferente del atacante y, aunque la vulnerabilidad está presente en Sun ZFS Storage Appliance Kit (AK), los ataques podrían afectar seriamente a productos adicionales. Los ataques exitosos a esta vulnerabilidad pueden resultar en la toma de control de Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Impactos en la confidencialidad, integridad y disponibilidad). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
],
"lastModified": "2026-06-17T00:59:24.743",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:oracle:sun_zfs_storage_appliance_kit_software:2013:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D06E5C2E-66BF-434F-9137-B256450C00EE"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secalert_us@oracle.com"
}