CVE-2016-9347
Estado: ModificadaMedia (5)—
Ha sido descubierto un problema en Emerson SE4801T0X Redundant Wireless I/O Card V13.3 y SE4801T1X Simplex Wireless I/O Card V13.3. DeltaV Wireless I/O Cards (WIOC) que ejecutan el firmware disponible en el sistema DeltaV, versión v13.3, tienen la funcionalidad SSH (Secure Shell) habilitada innecesariamente.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L
- Puntuación base: 5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.49%
- Percentil entre todas las CVEs puntuadas: 40
- Fecha de la puntuación: 8/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-254
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2016-9347",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5.4,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 5.5,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "Emerson DeltaV Wireless I/O Card 13.3",
"versions": [
{
"status": "affected",
"version": "Emerson DeltaV Wireless I/O Card 13.3"
}
]
}
]
}
],
"published": "2017-02-13T21:59:01.830",
"references": [
{
"url": "http://www.securityfocus.com/bid/94586",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-334-03",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/94586",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-334-03",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-254"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Emerson SE4801T0X Redundant Wireless I/O Card V13.3, and SE4801T1X Simplex Wireless I/O Card V13.3. DeltaV Wireless I/O Cards (WIOC) running the firmware available in the DeltaV system, release v13.3, have the SSH (Secure Shell) functionality enabled unnecessarily."
},
{
"lang": "es",
"value": "Ha sido descubierto un problema en Emerson SE4801T0X Redundant Wireless I/O Card V13.3 y SE4801T1X Simplex Wireless I/O Card V13.3. DeltaV Wireless I/O Cards (WIOC) que ejecutan el firmware disponible en el sistema DeltaV, versión v13.3, tienen la funcionalidad SSH (Secure Shell) habilitada innecesariamente."
}
],
"lastModified": "2026-06-17T00:55:51.530",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:emerson:se4801t0x_redundant_wireless_i\\/o_card_firmware:13.3:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D0027A39-A16C-4BF3-BCFF-27EAEF2CFA20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:emerson:se4801t0x_redundant_wireless_i\\/o_card:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1F515BD5-A516-4EF6-83BD-1D4FB13554A6"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:emerson:se4801t1x_simplex_wireless_i\\/o_card_firmware:13.3:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B244549D-2E37-4C53-B53A-FD99838A18AC"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:emerson:se4801t1x_simplex_wireless_i\\/o_card:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D40F2767-6A1A-44BB-98F6-684A05BB2C0C"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}