« Back to list

CVE-2016-4403

Status: ModifiedCritical (9.8)—

A security vulnerability was identified in the Filter SDK component of HP KeyView earlier than v11.2. The vulnerability could be exploited remotely to allow code execution via memory corruption.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2016-4403",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "security-alert@hpe.com",
      "affectedData": [
        {
          "vendor": "Hewlett Packard Enterprise",
          "product": "HP Keyview",
          "versions": [
            {
              "status": "affected",
              "version": "earlier than v11.2"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-08-06T20:29:00.600",
  "references": [
    {
      "url": "http://www.securityfocus.com/bid/94184",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "security-alert@hpe.com"
    },
    {
      "url": "http://www.securitytracker.com/id/1037235",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "security-alert@hpe.com"
    },
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-c05325836",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security-alert@hpe.com"
    },
    {
      "url": "http://www.securityfocus.com/bid/94184",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securitytracker.com/id/1037235",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-c05325836",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A security vulnerability was identified in the Filter SDK component of HP KeyView earlier than v11.2. The vulnerability could be exploited remotely to allow code execution via memory corruption."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad de seguridad en el componente Filter SDK de HP KeyView en versiones anteriores a la v11.2. La vulnerabilidad podría explotarse remotamente para permitir la ejecución de código mediante una corrupción de memoria."
    }
  ],
  "lastModified": "2026-06-17T00:47:30.010",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hp:keyview:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C685D689-6D7B-4605-9CB4-66A9302817BD",
              "versionEndExcluding": "11.2"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com"
}