CVE-2015-1014

Estado: ModificadaAlta (7.3)—

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2015-1014",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.4,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.4,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.3,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.3
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "OFS v3.5",
          "versions": [
            {
              "status": "affected",
              "version": "< v7.40 of SCADA Expert Vijeo Citect/CitectSCADA"
            },
            {
              "status": "affected",
              "version": "< v7.30 of Vijeo Citect/CitectSCADA"
            },
            {
              "status": "affected",
              "version": "< v7.20 of Vijeo Citect/CitectSCADA."
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-03-25T19:29:00.337",
  "references": [
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version."
    },
    {
      "lang": "es",
      "value": "Una explotación exitosa de estas vulnerabilidades requiere que el usuario local suba un archivo DLL manipulado en el directorio de sistemas en los servidores que ejecutan Schneider Electric OFS v3.5 con la versión v7.40 de SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 con la versión v7.30 de Vijeo Citect/CitectSCADA y OFS v3.5 con la versiónv7.20 de Vijeo Citect/CitectSCADA. Si la aplicación intenta abrir ese archivo, podría cerrarse inesperadamente o permitir al atacante ejecutar código arbitrario. Schneider Electric recomienda que los usuarios vulnerables actualicen el OFS a la versión V3.5 e instalen el paquete de servicios más reciente (SP 6 o más reciente) para la versión asociada."
    }
  ],
  "lastModified": "2026-06-17T00:21:38.587",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:opc_factory_server:3.5:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "AB358AD4-EDE9-4AB0-A43E-72C63997F240"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.20:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "85E1560F-CE61-43C7-A27C-D3686CA72BD0"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.30:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "718E137A-94A1-46E2-B81E-D0812BC4894E"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.40:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A21DF1A9-A957-419F-A84B-EB73F1FB15FA"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:scada_expert_vijeo_citect:7.20:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "ABE06649-0C82-4D18-8587-3B26C4F366EC"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:scada_expert_vijeo_citect:7.30:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A005118C-AB06-4F8C-AED5-FB186534C48D"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:scada_expert_vijeo_citect:7.40:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7DCB46CA-EBF8-4318-9671-B5A5D6DED3CE"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}