Status: ModifiedHigh (7.5)—

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2014-8513",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": true,
        "impactScore": 6.4,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2014-12-27T15:59:02.777",
  "references": [
    {
      "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188.  NOTE: this may be clarified later based on details provided by researchers."
    },
    {
      "lang": "es",
      "value": "Desbordamiento de buffer en el control ActiveX en MDraw30.ocx en Schneider Electric ProClima anterior a 6.1.7 permite a atacantes remotos ejecutar código arbitrario a través de vectores sin especificar, una vulnerabilidad diferente a CVE-2014-8514 y CVE-2014-9188. NOTA: esto se puede aclarar después en base a los detalles proporcionados por los investigadores."
    }
  ],
  "lastModified": "2026-06-17T00:16:51.073",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider_electric:proclima:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "47B0392E-5225-40CD-B1CB-8761B69A743E",
              "versionEndIncluding": "6.0.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}