« Back to list

CVE-2014-0759

Status: ModifiedMedium (5.9)—

Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2014-0759",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2014-0759",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-05-28T17:30:21.642177Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "ics-cert@hq.dhs.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.9,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.4,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.9,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.4,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.9,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 3.4,
        "exploitabilityScore": 2.5
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "Floating License Manager",
          "versions": [
            {
              "status": "affected",
              "version": "V1.0.0",
              "versionType": "custom",
              "lessThanOrEqual": "V1.4.0"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2014-02-28T06:18:54.260",
  "references": [
    {
      "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-015-01",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-058-01",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-015-01",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-058-01",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-428"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de búsqueda de ruta en Windows sin entrecomillar en Schneider Electric Floating License Manager 1.0.0 hasta 1.4.0 permite a usuarios locales ganar privilegios a través de una aplicación de caballo de troya con un nombre compuesto de una subcadena inicial de una ruta que contiene un caracter de espacio."
    }
  ],
  "lastModified": "2026-06-17T00:03:35.343",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:floating_license_manager:1.0.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7976E9AC-B3A5-439D-8E0C-90F540A93CF9"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:floating_license_manager:1.4.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D2F7F55C-E444-4331-9ECC-F8D92D458AD2"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "evaluatorComment": "Per: http://cwe.mitre.org/data/definitions/428.html\n\n\"CWE-428: Unquoted Search Path or Element\"",
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "evaluatorSolution": "Per: http://ics-cert.us-cert.gov/advisories/ICSA-14-058-01\n\n\"This license manager is used in the following Schneider Electric products:\n\n    Power Monitoring Expert,\n    Struxureware process Expert (PES),\n    Struxureware process Expert libraries,\n    Vijeo Citect (SCADA), and\n    Vijeo Citect Historian.\""
}