« Volver al listado

CVE-2013-7333

Estado: ModificadaAlta (7.5)—

A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices connected to the targeted switch.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2013-7333",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 6.9,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-10-23T17:15:10.613",
  "references": [
    {
      "url": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices connected to the targeted switch."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en la versión 0.90 del software del controlador SDN de Open Floodlight, podría permitir que un atacante con acceso a la red de control de OpenFlow desconecte selectivamente los switches individuales desde el controlador SDN, causando degradación y eventualmente la denegación del acceso de red a todos los dispositivos conectados al switch objetivo."
    }
  ],
  "lastModified": "2026-06-17T00:01:46.537",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:projectfloodlight:open_sdn_controller:0.90:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D272E939-9490-4C5B-87CB-8AE4FE9D122B"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}