Status: ModifiedMedium (5)—

The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2013-6143",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2014-01-31T16:55:05.077",
  "references": [
    {
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01",
      "tags": [
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        },
        {
          "lang": "en",
          "value": "CWE-399"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic."
    },
    {
      "lang": "es",
      "value": "El Schneider Electric Telvent SAGE 3030 RTU con filmware C3413-500-001D3_P4 y C3413-500-001F0_PB permite a atacantes remotos causar una denegación de servicio (interrupción temporal y consumo de CPU) a través de tráfico DNP3 malformado."
    }
  ],
  "lastModified": "2026-06-17T00:00:00.453",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:telvent_sage_3030_firmware:c3413-500-001d3_p4:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3C4F6DA6-C66C-4EBC-B073-47E1692EBC80"
            },
            {
              "criteria": "cpe:2.3:o:schneider-electric:telvent_sage_3030_firmware:c3413-500-001f0_pb:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0A8C5D42-04B6-46EA-A018-28ADBEE52F09"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "evaluatorComment": "Vendor advisory:\nhttps://infrastructurecommunity.schneider-electric.com/servlet/JiveServlet/downloadBody/2966-102-1-4299/SAGE%20RTU%20DNP%20Security%20Bulletin%20123013%200102.pdf",
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}