CVE-2012-4690
Estado: ModificadaAlta (7.1)—
Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status bits.
CVSS
- Versión: 2.0
- Vector: AV:N/AC:M/Au:N/C:N/I:N/A:C
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 4.05%
- Percentil entre todas las CVEs puntuadas: 90
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-16
Referencias
- http://ics-cert.us-cert.gov/advisories/ICSA-12-342-01A
- http://www.us-cert.gov/control_systems/pdf/ICSA-12-342-01.pdf
- https://rockwellautomation.custhelp.com/app/answers/detail/a_id/511407
- http://ics-cert.us-cert.gov/advisories/ICSA-12-342-01A
- http://www.us-cert.gov/control_systems/pdf/ICSA-12-342-01.pdf
- https://rockwellautomation.custhelp.com/app/answers/detail/a_id/511407
JSON original (NVD)
Mostrar
{
"id": "CVE-2012-4690",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.1,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2012-12-08T15:55:01.007",
"references": [
{
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-342-01A",
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-342-01.pdf",
"tags": [
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/511407",
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-342-01A",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-342-01.pdf",
"tags": [
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/511407",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-16"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status bits."
},
{
"lang": "es",
"value": "Controlador Rockwell Automation Allen-Bradley MicroLogix v1100, v1200, v1400 y v1500; plataforma de controladores SLC 500 y PLC-5, cuando el estado Static no está activado, permite a atacantes remotos provocar una denegación de servicio a través de mensajes que desencadenan la modificación de bits de estado."
}
],
"lastModified": "2026-06-16T23:45:35.173",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FA98842B-9D09-4C37-AB34-4E9FA566BAD8"
},
{
"criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1200:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C845DE9C-D4AF-4234-8DB6-1E335C909BAF"
},
{
"criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FFF2EF59-F451-490D-A7AF-E66D11493948"
},
{
"criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1500:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7D9F8B08-21FD-4D6B-9F5E-D3CA4A8F323C"
},
{
"criteria": "cpe:2.3:h:rockwellautomation:plc-5_controller:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AEDAA951-691B-4ADB-861D-854E6368F51A"
},
{
"criteria": "cpe:2.3:h:rockwellautomation:slc_500_controller:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD6D98F4-9A0B-46A4-903B-09830C65D487"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}