CVE-2012-3030
Status: ModifiedMedium (5)—
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
CVSS
- Version: 2.0
- Vector: AV:N/AC:L/Au:N/C:P/I:N/A:N
- Base score: 5
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 2.64%
- Percentile among all scored CVEs: 85
- Score date: 10/2/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (2)
CWEs
- CWE-264
References
- http://en.securitylab.ru/lab/PT-2012-43
- http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
- http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf
- http://en.securitylab.ru/lab/PT-2012-43
- http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
- http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf
Raw JSON (NVD)
Show
{
"id": "CVE-2012-3030",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2012-09-18T14:55:01.443",
"references": [
{
"url": "http://en.securitylab.ru/lab/PT-2012-43",
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf",
"tags": [
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://en.securitylab.ru/lab/PT-2012-43",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf",
"tags": [
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-264"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request."
},
{
"lang": "es",
"value": "WebNavigator en Siemens WinCC v7.0 SP3 y anteriores, como las usadas en SIMATIC PCS7 y otros productos, almacena información sensible bajo l directorio web raiz con un control de acceso no suficiente, lo que permite a atacantes remotos a leer (1) ficheros de registro o (2) ficheros de configuración a través de una petición directa."
}
],
"lastModified": "2026-06-16T23:42:32.257",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E8B894F4-9635-4436-BC0A-E43280426017"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5AC094B0-B1BE-436D-A8D3-2008D0CDE070",
"versionEndIncluding": "7.0"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B4CB277F-7ECB-4F44-8BB5-A3D350486EE7"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "616535F1-F609-408B-AE48-61ACF48748A1"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7F322FCB-32F4-4C5A-A7F5-F7EF41188C88"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "69822DB4-DC79-4F88-A470-5AC512C77377"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "996DE8BD-DD51-41EF-9882-C2BD2CC5FE53"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "945C8B46-4CDA-4143-889C-30E30E93DB29"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A33F9015-7058-419A-8762-CB2AE4ACF1A7"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E6271FCC-CCF6-4D31-801A-B4B0DC4639DD"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DF7A6B2B-D573-4285-B3B4-136F2BE7E710"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}