« Volver al listado

CVE-2012-0229

Estado: ModificadaAlta (10)—

The Data Archiver service in GE Intelligent Platforms Proficy Historian 4.5 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted session on TCP port 14000 to (1) ihDataArchiver.exe or (2) ihDataArchiver_x64.exe.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2012-0229",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 10,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ]
  },
  "affected": [
    {
      "source": "cret@cert.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2012-03-15T18:55:00.727",
  "references": [
    {
      "url": "http://secunia.com/advisories/48369",
      "source": "cret@cert.org"
    },
    {
      "url": "http://support.ge-ip.com/support/index?page=kbchannel&id=S:KB14767",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cret@cert.org"
    },
    {
      "url": "http://www.securityfocus.com/bid/52437",
      "source": "cret@cert.org"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-032-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "cret@cert.org"
    },
    {
      "url": "http://secunia.com/advisories/48369",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://support.ge-ip.com/support/index?page=kbchannel&id=S:KB14767",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/52437",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-032-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Data Archiver service in GE Intelligent Platforms Proficy Historian 4.5 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted session on TCP port 14000 to (1) ihDataArchiver.exe or (2) ihDataArchiver_x64.exe."
    },
    {
      "lang": "es",
      "value": "El servicio Data Archiver service en GE Intelligent Platforms Proficy Historian v4.5 y anteriores permite a atacantes remotos provocar una denegación de servicio (corrupción de memoria) o posiblemente ejecutar código a través de una sesión TCP manipulada en el puerto 14000 sobre  (1) ihDataArchiver.exe o (2) ihDataArchiver_x64.exe.\r\n"
    }
  ],
  "lastModified": "2026-06-16T23:36:57.090",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BD7154F7-EB35-45EF-96E8-9C7046B6B6F3",
              "versionEndIncluding": "4.5"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:1.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "19CF588D-73FE-458B-8612-D4CFCEEC00CE"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "89EC63B5-5F9A-48CB-B609-593300867800"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:2.0:beta:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8CA98EEF-CB31-4D5D-9168-D47E10C41FF8"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "24392BA2-A311-4ED5-B724-E9D156FCDEAB"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "612B7F05-3C6D-43CA-8D6C-F0A887789EF5"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.5:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6D29C00B-B754-47C5-BBD0-D63DDD252DA6"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6BC9F852-EA9A-497D-9ED2-DAF926D0440A"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cret@cert.org"
}