CVE-2012-0221

Medium (5)—Exploit
Routine follow-upSeverity Medium 5. A public proof of concept exists, but no active exploitation is known.
Severity5Medium · CVSS 2.0
Exploitation probability9.66 %higher than 96% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 05:00 PM
Public exploitAvailablePublished on Exploit-DB

The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet.

Timeline

Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.

  1. First public exploit: Published on Exploit-DB
  2. CVE record published in NVD
  3. Record last modified in NVD

Public exploits

Exploit code or detection templates are publicly available. This is not the same as confirmed active exploitation (KEV), but it raises the risk: patch with priority.

Affected technologies (2)

NVD record

NVD status
Modified
Published
Apr 2, 2012
Last modified
Jun 16, 2026
CVSS vector
AV:N/AC:L/Au:N/C:N/I:N/A:P
Weakness (CWE)
CWE-20

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2012-0221",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ]
  },
  "affected": [
    {
      "source": "cret@cert.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2012-04-02T18:55:01.043",
  "references": [
    {
      "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937",
      "source": "cret@cert.org"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "cret@cert.org"
    },
    {
      "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet."
    },
    {
      "lang": "es",
      "value": "El servicio FactoryTalk (FT) RNADiagReceiver en Rockwell Automation Allen-Bradley FactoryTalk CPR9 hasta SR5 y RSLogix 5000 17 hasta 20 no gestiona de forma adecuada el valor de retorno de una función específica, lo que permite a atacantes remotos provocar una denegación de servicio (corte de servicio) a través de un paquete manipulado."
    }
  ],
  "lastModified": "2026-06-16T23:36:55.260",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk:cpr9:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A4CDEE93-7510-44B2-9C6F-57D896F2BDCD"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk:cpr9_sr5:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D3288C19-0AA1-45AC-A224-0483587645E0"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:17:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A3E1F2B5-8BD1-49DF-AEF1-8E4B47C8F5E4"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:18:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C4165EAF-CA42-4A8D-BE59-275DFB21EA80"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:19:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D1D65EF8-F725-4250-9319-08B6625928ED"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:20:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E984E344-7B3A-4A0A-96A9-D2C2E4802ECA"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cret@cert.org"
}