« Volver al listado

CVE-2010-2772

Estado: ModificadaAlta (7.8)—

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2010-2772",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.9,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": true,
        "exploitabilityScore": 3.4,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2010-07-22T05:43:58.250",
  "references": [
    {
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725",
      "tags": [
        "Press/Media Coverage"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr",
      "tags": [
        "Press/Media Coverage"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/",
      "tags": [
        "Press/Media Coverage"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://secunia.com/advisories/40682",
      "tags": [
        "Broken Link"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c",
      "tags": [
        "Not Applicable"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1",
      "tags": [
        "Broken Link"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.f-secure.com/weblog/archives/00001987.html",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.securityfocus.com/bid/41753",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.vupen.com/english/advisories/2010/1893",
      "tags": [
        "Broken Link"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22",
      "tags": [
        "Exploit",
        "Issue Tracking"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/",
      "tags": [
        "Press/Media Coverage",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725",
      "tags": [
        "Press/Media Coverage"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr",
      "tags": [
        "Press/Media Coverage"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/",
      "tags": [
        "Press/Media Coverage"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://secunia.com/advisories/40682",
      "tags": [
        "Broken Link"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c",
      "tags": [
        "Not Applicable"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1",
      "tags": [
        "Broken Link"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.f-secure.com/weblog/archives/00001987.html",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/41753",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.vupen.com/english/advisories/2010/1893",
      "tags": [
        "Broken Link"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22",
      "tags": [
        "Exploit",
        "Issue Tracking"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/",
      "tags": [
        "Press/Media Coverage",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."
    },
    {
      "lang": "es",
      "value": "Siemens Simatic WinCC y sistemas PCS 7 SCADA utiliza una contraseña no modificable en el código, lo cual permite a usuarios locales acceder a una base de datos interna (back-end) y obtener privilegios, como se demuestra en julio de 2010 por el gusano Stuxnet, una vulnerabilidad diferente de CVE-2010-2568."
    }
  ],
  "lastModified": "2026-06-16T23:21:29.277",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:6.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9BD0EB37-CFA4-49AE-A952-1A4E2E2EE998"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00"
            }
          ],
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:6.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "963E0E16-2A77-45C8-8708-46B4158C40D0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:6.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2C026414-5F0C-48E7-A93D-12E2E33AB6CB"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BD419DE7-CB43-42E7-ACCC-82EA4913E8D2"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "036B082A-1B48-4BA0-A915-4344C70E430D"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D7885AE5-023B-45BC-8E4A-CF796B5757C2"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}