CVE-2007-1249
Status: ModifiedMedium (6.8)—
MoveSortedContentAction in C1 Financial Services Contelligent 9.1.4 does not check "the additional environment security configuration," which allows remote attackers with write permissions to reorder components.
CVSS
- Version: 2.0
- Vector: AV:N/AC:M/Au:N/C:P/I:P/A:P
- Base score: 6.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 1.08%
- Percentile among all scored CVEs: 64
- Score date: 10/8/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- CWE-362
References
- http://osvdb.org/33497
- http://secunia.com/advisories/24364
- http://www.contelligent.com/contell/cms/c1web/contelligent/site/contelligent/changelog.html?fromRelease=9.1.4
- http://www.securityfocus.com/bid/22785
- http://www.vupen.com/english/advisories/2007/0814
- https://exchange.xforce.ibmcloud.com/vulnerabilities/32775
- http://osvdb.org/33497
- http://secunia.com/advisories/24364
- http://www.contelligent.com/contell/cms/c1web/contelligent/site/contelligent/changelog.html?fromRelease=9.1.4
- http://www.securityfocus.com/bid/22785
- http://www.vupen.com/english/advisories/2007/0814
- https://exchange.xforce.ibmcloud.com/vulnerabilities/32775
Raw JSON (NVD)
Show
{
"id": "CVE-2007-1249",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": true,
"userInteractionRequired": false
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2007-03-03T20:19:00.000",
"references": [
{
"url": "http://osvdb.org/33497",
"source": "cve@mitre.org"
},
{
"url": "http://secunia.com/advisories/24364",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.contelligent.com/contell/cms/c1web/contelligent/site/contelligent/changelog.html?fromRelease=9.1.4",
"source": "cve@mitre.org"
},
{
"url": "http://www.securityfocus.com/bid/22785",
"source": "cve@mitre.org"
},
{
"url": "http://www.vupen.com/english/advisories/2007/0814",
"source": "cve@mitre.org"
},
{
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/32775",
"source": "cve@mitre.org"
},
{
"url": "http://osvdb.org/33497",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://secunia.com/advisories/24364",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.contelligent.com/contell/cms/c1web/contelligent/site/contelligent/changelog.html?fromRelease=9.1.4",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/22785",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.vupen.com/english/advisories/2007/0814",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/32775",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-362"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "MoveSortedContentAction in C1 Financial Services Contelligent 9.1.4 does not check \"the additional environment security configuration,\" which allows remote attackers with write permissions to reorder components."
},
{
"lang": "es",
"value": "MoveSortedContentAction en C1 Financial Services Contelligent 9.1.4 no valida \"el entorno de configuración de seguridad adicional,\" lo cual permite a atacantes remotos con permisos de escritura reordenar componentes."
}
],
"lastModified": "2026-06-16T22:37:13.613",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contelligent:c1_financial_services:9.1.4:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "37240361-0C19-4D20-9283-3D43AC861BC8"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}