« Volver al listado

CVE-2003-1507

Estado: ModificadaAlta (10)—

Planet Technology WGSD-1020 and WSW-2401 Ethernet switches use a default "superuser" account with the "planet" password, which allows remote attackers to gain administrative access.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2003-1507",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 10,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": true,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2003-12-31T05:00:00.000",
  "references": [
    {
      "url": "http://securitytracker.com/id?1007924",
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.securityfocus.com/archive/1/341329",
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.securityfocus.com/bid/8837",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/13446",
      "source": "cve@mitre.org"
    },
    {
      "url": "http://securitytracker.com/id?1007924",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/archive/1/341329",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/8837",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/13446",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Planet Technology WGSD-1020 and WSW-2401 Ethernet switches use a default \"superuser\" account with the \"planet\" password, which allows remote attackers to gain administrative access."
    }
  ],
  "lastModified": "2026-06-16T22:04:33.760",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:planet_technology_corp:wgsd-1020:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B4C229FF-0561-44B8-ACEB-F19D167F6A35"
            },
            {
              "criteria": "cpe:2.3:h:planet_technology_corp:wsw-2401:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D48F149A-B313-4359-9790-6665AE29BF3F"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}