| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2022-25622 | Alta (7.5) | 0.90% | — | 12 abr 2022 | The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to… |
| CVE-2019-10936 | Alta (7.5) | 2.1% | — | 10 oct 2019 | Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition. |
| CVE-2016-2201 | Media (5.3) | 2.9% | — | 8 feb 2016 | Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102. |
| CVE-2016-2200 | Alta (7.5) | 6.4% | — | 8 feb 2016 | Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service (STOP mode transition) via crafted packets on TCP port 102. |
| CVE-2014-5074 | Alta (7.1) | 9.7% | — | 17 ago 2014 | Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets. |
| CVE-2014-2259 | Alta (7.8) | 4.5% | — | 16 mar 2014 | Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets. |
| CVE-2014-2257 | Alta (7.8) | 3.5% | — | 16 mar 2014 | Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets. |
| CVE-2014-2255 | Alta (7.8) | 4.5% | — | 16 mar 2014 | Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets. |
| CVE-2014-2253 | Media (6.1) | 1.0% | — | 16 mar 2014 | Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets. |
| CVE-2014-2251 | Alta (8.3) | 2.7% | — | 16 mar 2014 | The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection… |
| CVE-2014-2249 | Media (5.8) | 1.3% | — | 16 mar 2014 | Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the… |
| CVE-2014-2248 | Media (4.3) | 2.2% | — | 16 mar 2014 | Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing… |
| CVE-2014-2247 | Media (5.8) | 2.4% | — | 16 mar 2014 | The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors. |
| CVE-2014-2246 | Media (4.3) | 2.2% | — | 16 mar 2014 | Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified… |