« Back to list

Siemens

Siemens Simatic S7-1200 CPU 1215 FC Firmware: vulnerabilities and CVEs

Siemens Simatic S7-1200 CPU 1215 FC Firmware has 10 published vulnerabilities, 0 of them in the last 12 months. 0 are rated critical and 0 are listed by CISA as actively exploited.

CVEs10
Last 12 months0
Critical0
Actively exploited0

All vulnerabilities in the catalogue →⭐ Follow this technology

Latest vulnerabilities

CVESeverityEPSSActive exploitationPublishedDescription
CVE-2021-44695High (7.5)0.74%—Dec 13, 2022
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
CVE-2021-44694High (7.5)0.63%—Dec 13, 2022
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
CVE-2021-44693High (7.5)0.74%—Dec 13, 2022
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
CVE-2021-40365High (7.5)0.90%—Dec 13, 2022
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
CVE-2022-30694Low (3.5)0.31%—Nov 8, 2022
The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery…
CVE-2021-3449Medium (5.9)64%—Mar 25, 2021
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the…
CVE-2013-2780High (7.8)2.4%—Apr 22, 2013
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
CVE-2013-0700High (7.8)2.4%—Apr 22, 2013
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
CVE-2012-3040Medium (4.3)2.6%—Oct 10, 2012
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
CVE-2012-3037Medium (4.3)1.5%—Sep 25, 2012
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this…