Siemens Simatic S7-1200 CPU 1214 FC Firmware tiene 10 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 0 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE10
Últimos 12 meses0
Críticas0
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2021-44695 | Alta (7.5) | 0.74% | — | 13 dic 2022 | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |
| CVE-2021-44694 | Alta (7.5) | 0.63% | — | 13 dic 2022 | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |
| CVE-2021-44693 | Alta (7.5) | 0.74% | — | 13 dic 2022 | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |
| CVE-2021-40365 | Alta (7.5) | 0.90% | — | 13 dic 2022 | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |
| CVE-2022-30694 | Baja (3.5) | 0.31% | — | 8 nov 2022 | The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery… |
| CVE-2021-3449 | Media (5.9) | 64% | — | 25 mar 2021 | An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the… |
| CVE-2013-2780 | Alta (7.8) | 2.4% | — | 22 abr 2013 | Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port). |
| CVE-2013-0700 | Alta (7.8) | 2.4% | — | 22 abr 2013 | Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port). |
| CVE-2012-3040 | Media (4.3) | 2.6% | — | 10 oct 2012 | Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI. |
| CVE-2012-3037 | Media (4.3) | 1.5% | — | 25 sept 2012 | The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this… |