Siemens
Siemens Simatic Ipc377g Firmware: vulnerabilities and CVEs
Siemens Simatic Ipc377g Firmware has 9 published vulnerabilities, 0 of them in the last 12 months. 0 are rated critical and 0 are listed by CISA as actively exploited.
CVEs9
Last 12 months0
Critical0
Actively exploited0
All vulnerabilities in the catalogue →⭐ Follow this technology
Latest vulnerabilities
| CVE | Severity | EPSS | Active exploitation | Published | Description |
|---|---|---|---|---|---|
| CVE-2021-42554 | High (8.2) | 0.33% | — | Feb 3, 2022 | An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before… |
| CVE-2021-42059 | Medium (6.7) | 0.35% | — | Feb 3, 2022 | An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow… |
| CVE-2021-41838 | High (8.2) | 0.30% | — | Feb 3, 2022 | An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs… |
| CVE-2021-41837 | High (8.2) | 0.28% | — | Feb 3, 2022 | An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or… |
| CVE-2021-33627 | High (8.2) | 0.33% | — | Feb 3, 2022 | An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software… |
| CVE-2021-33625 | High (7.5) | 0.32% | — | Feb 3, 2022 | An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the… |
| CVE-2020-5953 | High (7.5) | 0.28% | — | Feb 3, 2022 | A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is… |
| CVE-2021-33626 | High (7.8) | 0.31% | — | Oct 1, 2021 | A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an… |
| CVE-2020-27339 | Medium (6.7) | 0.32% | — | Jun 16, 2021 | In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions… |