Siemens
Siemens Scalance Xp-200 Firmware: vulnerabilidades y CVE
Siemens Scalance Xp-200 Firmware tiene 12 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 1 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE12
Últimos 12 meses0
Críticas1
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2022-36325 | Media (4.8) | 0.94% | — | 10 ago 2022 | Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a… |
| CVE-2022-36324 | Alta (7.5) | 1.7% | — | 10 ago 2022 | Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for… |
| CVE-2022-36323 | Alta (7.2) | 1.7% | — | 10 ago 2022 | Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. |
| CVE-2020-28400 | Alta (8.7) | 1.9% | — | 13 jul 2021 | Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. |
| CVE-2021-3449 | Media (5.9) | 64% | — | 25 mar 2021 | An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the… |
| CVE-2021-25667 | Alta (8.8) | 0.86% | — | 15 mar 2021 | A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All… |
| CVE-2019-19301 | Alta (7.5) | 1.4% | — | 14 abr 2020 | A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM,… |
| CVE-2019-13946 | Alta (7.5) | 1.5% | — | 11 feb 2020 | Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of… |
| CVE-2019-13924 | Media (5.4) | 0.83% | — | 11 feb 2020 | A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family… |
| CVE-2019-10927 | Media (6.5) | 1.2% | — | 13 ago 2019 | A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with… |
| CVE-2019-6569 | Crítica (9.1) | 1.3% | — | 26 mar 2019 | The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems… |
| CVE-2017-12736 | Alta (8.8) | 1.1% | — | 26 dic 2017 | After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to… |