Siemens
Siemens Scalance Xc216-4c G EEC Firmware: vulnerabilidades y CVE
Siemens Scalance Xc216-4c G EEC Firmware tiene 11 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 2 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE11
Últimos 12 meses0
Críticas2
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2023-44317 | Alta (8.6) | 0.38% | — | 14 nov 2023 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB… |
| CVE-2022-46143 | Media (5.1) | 0.72% | — | 13 dic 2022 | Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. |
| CVE-2022-46142 | Media (5.2) | 0.27% | — | 13 dic 2022 | Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. |
| CVE-2022-46140 | Alta (7.1) | 0.24% | — | 13 dic 2022 | Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. |
| CVE-2022-36325 | Media (4.8) | 0.94% | — | 10 ago 2022 | Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a… |
| CVE-2022-36324 | Alta (7.5) | 1.7% | — | 10 ago 2022 | Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for… |
| CVE-2022-36323 | Alta (7.2) | 1.7% | — | 10 ago 2022 | Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. |
| CVE-2020-28391 | Media (5.9) | 1.1% | — | 12 ene 2021 | A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE… |
| CVE-2020-25226 | Crítica (9.8) | 1.7% | — | 12 ene 2021 | A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web… |
| CVE-2020-15800 | Crítica (9.8) | 1.7% | — | 12 ene 2021 | A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE… |
| CVE-2020-15799 | Media (6.5) | 1.1% | — | 12 ene 2021 | A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The… |