Schneider-electric
Schneider-electric Unity PRO: vulnerabilidades y CVE
Schneider-electric Unity PRO tiene 7 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 1 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE7
Últimos 12 meses0
Críticas1
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2020-7560 | Alta (8.6) | 1.4% | — | 11 dic 2020 | A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the… |
| CVE-2020-7475 | Crítica (9.8) | 1.6% | — | 23 mar 2020 | A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix),… |
| CVE-2019-6855 | Alta (7.3) | 0.95% | — | 6 ene 2020 | Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions… |
| CVE-2016-8354 | Alta (7) | 1.1% | — | 13 feb 2017 | An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are… |
| CVE-2014-9200 | Alta (7.5) | 5.6% | — | 1 feb 2015 | Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication… |
| CVE-2013-0662 | Alta (9.3) | 22% | — | 1 abr 2014 | Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application… |
| CVE-2011-3330 | Alta (7.2) | 1.3% | — | 4 nov 2011 | Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor… |
Otros productos de Schneider-electric
Struxureware Data Center Expert · 49Interactive Graphical Scada System · 43Modicon M580 Firmware · 41Modicon M340 Firmware · 39Modicon M340 Bmxp342020 Firmware · 32Modicon M340 Bmxp3420302 Firmware · 28Modicon M340 Bmxp341000 Firmware · 27Ecostruxure Control Expert · 26Modicon M340 Bmxp342000 Firmware · 25Modicon Quantum Firmware · 25Modicon M340 Bmxp3420102 Firmware · 25Easergy T300 Firmware · 24