Schneider-electric
Schneider-electric Guicon: vulnerabilidades y CVE
Schneider-electric Guicon tiene 6 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 0 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE6
Últimos 12 meses0
Críticas0
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2021-22809 | Media (5.5) | 0.65% | — | 28 ene 2022 | A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric… |
| CVE-2021-22808 | Alta (7.8) | 0.85% | — | 28 ene 2022 | A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon… |
| CVE-2021-22807 | Alta (7.8) | 0.81% | — | 28 ene 2022 | A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric… |
| CVE-2018-7815 | Alta (7.8) | 1.1% | — | 6 feb 2019 | A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on c3core.dll which could cause remote code to be executed when parsing a GD1 file |
| CVE-2018-7814 | Alta (7.8) | 1.2% | — | 6 feb 2019 | A Stack-based Buffer Overflow (CWE-121) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) which could cause remote code to be executed when parsing a GD1 file |
| CVE-2018-7813 | Alta (7.8) | 1.1% | — | 6 feb 2019 | A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on pcwin.dll which could cause remote code to be executed when parsing a GD1 file |
Otros productos de Schneider-electric
Struxureware Data Center Expert · 49Interactive Graphical Scada System · 43Modicon M580 Firmware · 41Modicon M340 Firmware · 39Modicon M340 Bmxp342020 Firmware · 32Modicon M340 Bmxp3420302 Firmware · 28Modicon M340 Bmxp341000 Firmware · 27Ecostruxure Control Expert · 26Modicon M340 Bmxp342000 Firmware · 25Modicon Quantum Firmware · 25Modicon M340 Bmxp3420102 Firmware · 25Easergy T300 Firmware · 24