Philips Patient Information Center IX: vulnerabilidades y CVE

Philips Patient Information Center IX tiene 11 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 0 son críticas y 0 figuran en el catálogo de explotación activa de CISA.

CVE11
Últimos 12 meses0
Críticas0
Explotadas activamente0

Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología

Últimas vulnerabilidades

CVESeveridadEPSSExplotación activaPublicadaDescripción
CVE-2021-43552Media (5.5)0.21%—27 dic 2021
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
CVE-2021-43550Media (6.5)0.22%—27 dic 2021
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX)…
CVE-2021-43548Media (6.5)0.37%—27 dic 2021
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2020-16224Media (6.5)0.59%—11 sept 2020
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of…
CVE-2020-16220Media (4.3)0.28%—11 sept 2020
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does…
CVE-2020-16216Media (6.5)0.70%—11 sept 2020
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly…
CVE-2020-16212Media (6.8)0.37%—11 sept 2020
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on…
CVE-2020-16228Media (6.4)0.37%—11 sept 2020
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the…
CVE-2020-16222Alta (8.8)0.55%—11 sept 2020
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the…
CVE-2020-16218Baja (3.5)0.65%—11 sept 2020
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and…
CVE-2020-16214Media (5)0.59%—11 sept 2020
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special…