« Volver al listado

Hitachienergy

Hitachienergy Microscada X Sys600: vulnerabilidades y CVE

Hitachienergy Microscada X Sys600 tiene 19 vulnerabilidades publicadas, 3 de ellas en los últimos 12 meses. 1 son críticas y 0 figuran en el catálogo de explotación activa de CISA.

CVE19
Últimos 12 meses3
Críticas1
Explotadas activamente0

Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología

Últimas vulnerabilidades

CVESeveridadEPSSExplotación activaPublicadaDescripción
CVE-2026-9854Alta (8.5)0.14%—3 sept 2026
A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control…
CVE-2026-9853Alta (8.5)0.14%—3 sept 2026
A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system…
CVE-2026-9852Media (4.6)0.21%—3 sept 2026
A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment…
CVE-2025-39205Alta (7.1)0.20%—24 jun 2025
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.
CVE-2025-39204Alta (8.5)0.36%—24 jun 2025
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user.
CVE-2025-39203Alta (7.1)0.22%—24 jun 2025
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop.
CVE-2025-39202Alta (8.3)0.23%—24 jun 2025
A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.
CVE-2025-39201Media (6.9)0.13%—24 jun 2025
A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.
CVE-2024-7941Media (4.3)0.34%—27 ago 2024
An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. By modifying the URL value to a malicious site, an attacker may successfully launch a phishing…
CVE-2024-7940Crítica (9.8)0.58%—27 ago 2024
The product exposes a service that is intended for local only to all network interfaces without any authentication.
CVE-2024-4872Alta (8.8)0.50%—27 ago 2024
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit…
CVE-2024-3982Alta (8.2)0.22%—27 ago 2024
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By…
CVE-2024-3980Alta (8.8)0.61%—27 ago 2024
The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or…
CVE-2022-3388Alta (7.8)0.29%—21 nov 2022
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. An authenticated user can launch an administrator level remote code execution irrespective of the…
CVE-2022-2277Alta (7.5)0.77%—14 sept 2022
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any…
CVE-2022-29922Alta (7.5)0.79%—14 sept 2022
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600,…
CVE-2022-29492Alta (7.5)0.75%—14 sept 2022
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed…
CVE-2022-1778Media (4.4)0.48%—14 sept 2022
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can…
CVE-2022-29490Alta (8.8)0.64%—12 sept 2022
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated…

🎯 Cómo se explota (técnicas ATT&CK)

  1. T1005 Data from Local System3
  2. T1068 Exploitation for Privilege Escalation3
  3. T1210 Exploitation of Remote Services3
  4. T1499.004 Application or System Exploitation1
  5. T1548 Abuse Elevation Control Mechanism1
  6. T1557 Adversary-in-the-Middle1

Número de CVE de esta tecnología asignadas a cada técnica de explotación o de impacto principal.

Otros productos de Hitachienergy