Gehealthcare
Gehealthcare Centricity Pacs-iw: vulnerabilidades y CVE
Gehealthcare Centricity Pacs-iw tiene 2 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 0 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE2
Últimos 12 meses0
Críticas0
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2011-5324 | Alta (10) | 1.7% | — | 4 ago 2015 | The TeraRecon server, as used in GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions, has a password of (1) shared for the shared user and (2) scan for the scan user, which has unspecified… |
| CVE-2011-5323 | Alta (10) | 1.7% | — | 4 ago 2015 | GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions has a password of A11enda1e for the sa SQL server user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this… |
Otros productos de Gehealthcare
Carescape Central Station Mai700 Firmware · 6Carescape Central Station Mas700 Firmware · 6Carescape Telemetry Server Mp100r Firmware · 6Apexpro Telemetry Server Firmware · 6Clinical Information Center Mp100r Firmware · 6Clinical Information Center Mp100d Firmware · 6Echopac · 5Optima Mr360 Firmware · 4Optima Ct540 Firmware · 3Optima Ct520 Firmware · 3Centricity Pacs Workstation · 3Brightspeed Edge Firmware · 2