Eq-3
Eq-3 Ccu3 Firmware: vulnerabilidades y CVE
Eq-3 Ccu3 Firmware tiene 10 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 4 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE10
Últimos 12 meses0
Críticas4
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2020-12834 | Crítica (9.8) | 11% | — | 15 may 2020 | eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to… |
| CVE-2019-14474 | Alta (7.5) | 1.9% | — | 7 ago 2019 | eQ-3 Homematic CCU3 3.47.15 and prior has Improper Input Validation in function 'Call()' of ReGa core logic process, resulting in the ability to start a Denial of Service. Due to Improper Authorization an attacker can… |
| CVE-2019-14473 | Alta (8.8) | 1.9% | — | 6 ago 2019 | eQ-3 Homematic CCU2 and CCU3 use session IDs for authentication but lack authorization checks. Consequently, a valid guest level or user level account can create a new admin level account, read the service messages,… |
| CVE-2019-14475 | Alta (7.5) | 2.0% | — | 5 ago 2019 | eQ-3 Homematic CCU2 2.47.15 and prior and CCU3 3.47.15 and prior use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID from CVE-2019-9583, resulting in the ability to read… |
| CVE-2019-10122 | Crítica (9.8) | 4.1% | — | 10 jul 2019 | eQ-3 HomeMatic CCU2 devices before 2.41.9 and CCU3 devices before 3.43.16 have buffer overflows in the ReGa ise GmbH HTTP-Server 2.0 component, aka HMCCU-179. This may lead to remote code execution. |
| CVE-2019-10121 | Crítica (9.8) | 4.6% | — | 10 jul 2019 | eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.15 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via the user authentication dialogue, aka… |
| CVE-2019-10120 | Alta (8.8) | 1.3% | — | 10 jul 2019 | On eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16, automatic login configuration (aka setAutoLogin) can be achieved by continuing to use a session ID after a logout, aka HMCCU-154. |
| CVE-2019-10119 | Crítica (9.8) | 2.0% | — | 10 jul 2019 | eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the… |
| CVE-2019-9727 | Alta (7.5) | 2.2% | — | 13 may 2019 | Unauthenticated password hash disclosure in the User.getUserPWD method in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to retrieve the GUI password hashes of GUI users. This vulnerability can be… |
| CVE-2019-9726 | Alta (7.5) | 16% | — | 13 may 2019 | Directory Traversal / Arbitrary File Read in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to read arbitrary files of the device's filesystem. This vulnerability can be exploited by unauthenticated… |